The insulated jacketed single-seat control valve adopts a top-guided unbalanced structure, featuring high strength, heavy load, an S-shaped flow path, small pressure drop loss, a large flow coefficient, a wide adjustable range, and high precision of flow characteristics.
The valve cage adopts a pressure-sealed valve seat design, solving problems such as difficult disassembly and large leakage of traditional threaded-in valve seats, and extending the service life. It adopts an open-flow design, and the medium tends to flow in the direction of valve opening. The controllability at small openings is good, and the deviation of flow characteristics is small. Special valve cages for noise reduction and anti-cavitation can be selected according to working condition requirements. Compared with 10P00, 10P60 is of the insulated jacketed type, mainly applied in occasions where the medium is easy to condense at normal temperature, such as when the medium is 石蜡 (paraffin). Steam is injected into the insulated jacket to heat the medium and maintain the flow of the medium.
-
Top-guided type
-
Unbalanced trim structure
-
Quick-dismantling structure
-
Equal percentage
-
Linear
-
Quick opening
-
PN1.6, 4.0Mpa (ANSI 150, 300LB)
-
ASME B16.104 V (Standard valve seat)
-
Pneumatic diaphragm actuator
-
Pneumatic piston actuator
-
Electric actuator